Rated voltage, V | 240 |
Lowest voltage level sufficient for the RN-16TM operation, V | 140 |
Highest permissible voltage, V | 320 |
Tripping voltage thresholds, V: – Lower threshold – Upper threshold | 150 – 210 230 – 320 |
Adjustment accuracy for the voltage tripping thresholds, V | 1 |
Illumination level adjustment range, Lx | 0 – 175 |
Voltage measurement accuracy, V (doesn’t exceed) | 1 |
Voltage hysteresis (returning ratio), V | + 5 |
Illumination level hysteresis (returning ratio), % | 12 |
Adjustable reaction time delay to Max/Min voltage interruptions, sec | 0– 9,9 |
Autoreclosing time delay (the RN-16TM will automatically close the contacts (turn ON the power load) as soon as the tripping parameters return to normal values), sec | 0– 9,9 |
Fixed reaction time to changes in illumination level, sec | 12 |
Accuracy of the time clocks, seconds per day (not exceed) | 3 |
Accuracy to adjust schedule time setting, min (not exceed) | 1 |
Maximal number of events per day, Include : – switching ON – switching OFF Events per week | 60 30 30 60х7=420 |
Endurance to the voltage absence (retention of settings when supply voltage is absent, no less than) | 1 month |
Protection degree: – relay – terminal | ІР40 ІР20 |
Commutation life for the output contacts: — under load 16А, no less than, operations — under load 5A, no less than, operations | 100 000 1 000 000 |
Power consumption (under load), VA, not more than | 3,0 |
Weight, not more than, kg | 0,150 |
Dimensions, mm | 50х88х65 |
Operating temperature, °С | from -10 to +55 |
Storage temperature, °С | from -20 to +70 |