SINGLE PHASE MOTOR PROTECTION DEVICE UBZ-115

Product Details:

Power (Watts or HP)0.5 – 2 kW (0.5 – 3 HP)
Motor Voltage220 – 240 V AC
Motor BrandAny
PhaseSingle Phase
Speed (Rpm)Any
Voltage TypeAC
Operating Voltage (V)160 – 280 V
Number of Poles2 Pole
ApplicationSingle phase motor protection, Submersible pump protection
Rated Current (Amps)0.5A to 25A programmable
Output TypeTriac + SPDT
BrandNOVATEK ELECTRO

Universal Single Phase Induction Electric Motor Protection Unit UBZ-115 is a microprocessor unit. UBZ-115 provides protection to single-phase induction electric motors with power up to 2 kW (25А). The UBZ-115 unit is designed to provide permanent control of mains voltage parameters and current effective value, which is consumed by the 230V/50Hz motor. In the UBZ-115 provides an external input for remote start or stop the motor, and feature “soft start” the motor up to 5 seconds.

UBZ-115 provides protection in the following situations:

 when the mains voltage is of poor quality (over & under voltage);

 mechanical overloads of the motor (over current);

 when motor torque is lost (“dry stroke”);

 delayed start or rotor jamming;

 thermal overload (thermal model of the motor). For each separate type of fault, the unit allows to enable or disable an automatic reset (AR) of the motor.

Main technical specifications: 

Rated single phase supply voltage, V

~230

Minimum/maximum functional voltage, V

130 – 300

Protection against current overload (currents greater than 40A)

yes

MCB (Miniature Circuit Breaker), A

32 (class B)

Mains frequency, Hz

48 – 62

Harmonical configuration (nonsinusoidality) of power supply voltage

EN 61000-3-2

(IEC 1000-3-2)

Maximum load capacity, kW

5.5

Rated current, А

25

Maximum allowable start current, A

40

Trip threshold accuracy for current, ≤, % of rated current

3

Trip threshold accuracy for voltage, ≤, V

3

Hysteresis return on voltage, ≤, V

4

Data storage term, years, not less than

10

Current consumption (at 220 V), ≤, mA

200

Weight, ≤, kg

2.6

Overall dimensions, mm

252 х 188 х 125

Remote control (water level sensor) input

Clean contact

Motor control through

Relay 40A, 240V

Triac 40A, 800V

Output connections starting capacitor

Triac 40A, 800V

Device allocation

Control equipment and distribution

Typical operation

Continued

Device level protection

IP30

Index protection of electrical shock

0I

Climatic modification

UHL3.1

Permissible degree of pollution

II

Overvoltage category

II

Nominal voltage of isolation, V

450

Rated impulse withstand voltage, kV

2.5

Selectable space position

Vertical

The relays output terminals specification:

Cos ф

Max. current for U~ 240 В

Max. power

Max. voltage ~

Terminals material

1.0

40 A

7200 VA

240 V

AgSnO

Commutation resource of output terminals:

     – electrical resource 40A 240V AC, times, not less than

     – mechanical resource, times, not less than

100 thousand

10 million

Operating conditions:

The unit is designed for operation in the following conditions:

            – ambient temperature is from minus 25 to +55 °С;

            – storage temperature is from minus 45 to +70 °С;

            – atmospheric pressure is from 84 to 106.7 kPa;

            – relative air humidity (at 35 °С) is 30…90%.